SONY
37-7
All SONY Cameras 1 Set camera to factory
default via camera web
gui or SNC toolbox
before adding the
camera to NVR
2 Retrieving camera
configuration on NVR
does not required
authentication.
Due to SONY camera over-
configuration issues, camera
may not respond to the following
resolution change request. If this
happens, camera will return its
own setting.
For example:
From:
H.264@5fps 640x480
MJPEG@5fps 640x480
To:
H.264@5fps 720x576
MJPEG@5fps 640x480
Bit rate behavior is inconsistent
for different models
SONY camera CGI Get
commands does not require
authentication.
In this case, user will see the
newly requested resolution
setting listed on NVR. No error
message is displayed on NVR.
User must refresh NVR screen
and check camera setting via
camera web gui to confirm if
change request is executed
successfully.
Workaround:
Repeat command on NVR
Bit rate may not be set
successfully in NVR 4.3, 4.4 but
it will be normal in NVR 4.5
All Models The focus value is set from 0-
45056, which is not user-friendly.
Workaround is to enable
autofocus , or change settings on
Camera Web GUI
SONY Generic The SONY Camera Handler
supports generic cameras for
those unlisted models. If one
camera is not in the supported
list, but is compatible with the
SONY interface, it can be
supported as a generic camera.
Model(s) Known Camera
Limitation/Behavior
Notes
Kommentare zu diesen Handbüchern