American Dynamics Fixed Camera (Illustra 210, Illustra 600 and Illustra 610 Domes)
21-4 Camera Handler Release Notes
•Illustra 210 = H.264, Maximum available Fps, D1
•Illustra 600 = H.264, Maximum available Fps , 1280X720
•Illustra 610 = H.264, Maximum available Fps , 1920X1080
The camera will not add after password is changed and correct password group is selected. This
issue happens intermittently.
Any interruption to video stream on the I6x0 Minidome series (stream setting change, camera
reboot or camera loss of power) will result on Edge Connection being interrupted even if it will
still shows as active on NVR configuration. Just disable and enable the “Edge Motion Detection
Alarms” configuration by the NVR alarm tab will restore the connection.
Setting up Edge Motion on the i6x0 Mini-Dome Cameras via the set up below (Scenario 2) may
cause Edge Motion not to trigger correctly.Please follow the work around if you intend to set up
your camera using Scenario 2. Otherwise you can use Scenario 1.
1 Scenario 1 - Motion Triggers
Add camera as default Single Stream - H264
Enable Edge Motion and configure NVR alarms page (assuming motion is
already setup on the camera)
Motion will always trigger
Enable Stream 2 Alarm / Record as MJPEG (usually MJPEG, 7, CIF)
Motion will always trigger
2 Scenario 2 - Motion does not Trigger
Add camera as default Single Stream - H264
Enable Edge Motion and configure NVR alarms page (assuming motion is
already setup on the camera)
Motion will always trigger
Enable Stream 2 Alarm / Record as H264 also.
•Motion will not trigger.
At this stage the camera is in a state. Even if you now change Stream 2 to
MJPEG, Edge motion will still not trigger.
Workaround for Scenario 2:
After setting both streams to H264, go back to the Alarm Configuration page on
the NVR
Disable Edge Motion and Save
Re-enable Edge Motion and Save
Motion will now trigger.