Seitenansicht 102
Bosch
29-5
Due to camera limitation, when setting 1080P for MJPEG stream on the Autodome Jr 800HD, it
is shows 1920x1072.
If observing some delay in live and recorded video on Victor Client – we recommend configuring
the settings on camera GUI as:
Go to Settings/advanced/camera/encoder profile/Profile 1/Expert settings:
GOP structure = IP
Iframe distance = set slider to the same FPS value configured on the VE NVR.
Due to a camera issue for some Bosch cameras, for example Auto Dome Easy II IP, the camera
has an interlacing issue when using 4CIF resolution. In order to resolve the
issue, the camera
must be set to CIF resolution
(on both the camera GUI (Settings/advanced/camera/encoder
profile/Profile 1/Video resolution ) and VE NVR video stream configuration.
Known Issues
The FPS is only 2.75 when MJPEG streaming (25 fps) is in use. It is a known camera limitation.
Confirmed with Bosch support that for most of the Bosch cameras FPS can only reach up to 5
FPS.
Audio and video is not synchronized with MJPEG stream on victor client. This is due to the
MJPEG stream limitation on the FPS only reaching a low rate.
When setting Brightness and Contrast on the NBC-265-P, it returns an error message. This is
because it uses different CGI from other cameras, so these properties and functions are not
supported.
Frequent Video Loss for Bosch Dinion HD 1080p D/N IVA is caused by the default NVR storage
setting. The recommended mount option when setting up the NVR is:
nofail,noatime,nodiratime,attr2,nobarrier,noquota,allocsize=4M
GOP structure should be set to “IP” prior to adding cameras to NVR. Failure to configure this
setting may cause videoloss or issues with victor playback.
If the network connection between the NVR and the camera drops and then established again,
this may result in the camera/device not restarting correctly. The camera should be restarted
Due to an NVR web client known Issue, when Stream 2 is enabled with the same codec as
Stream 1, the setting is a copy of the Stream 1 settings. But Bosch dual H.264 stream support
has a different resolution list. So when the client applies, it shows and applies a different
resolution value on Stream 2.
Due to the NVR web client known issue, when setting the resolution for the second H.264
stream, set it on the advance edit page. This is due to the fact it is a copy setting of H.264 stream
1 on camera list page with editing status, and real available resolution may not be included in the
copy of the resolution list.
Due to camera known issue, for Dinion HD 1080P D/N IVA camera, set resolution 4CIF
(704x480) on H.264 Stream 1 and 768x432 on H.264 Stream 2, then the user only can get an
actual resolution 704x432 for H.264 Stream 1. And set resolution 768x432 on H.264 Stream 1
and 4CIF (704x480) on H.264 Stream 2, user can only get actual resolution of 704x432 for
H.264 Stream 1.
There is a green line at top of victor Unified Client live stream on Bosch AutoDome Jr 800HD.
This is a camera issue.
Playback video stuttering when rewinding/forwarding the H.264 video from AutoDome 800 Jr.
The camera setting is: NTSC, H.264, 1920x1080, FPS=30. Camera's firmware version is
39500570.