Page 34 P/N: 49211C © 2002 Detection Systems, Inc. All rights reserved. DS7240/DS7220 User's Guide
PART II: KEYPAD USER’S GUIDE: DS7445i LED KEYPAD
5.10 Force Arming the System
Force arming is not permitted for UL
applications.
I can perform this function.
I cannot perform this function.
Description
Force arming provides a method of overriding the
safety feature that prevents turning the system on
with a faulted zone(s).
5.10.1 Force Arming with Normal Exit Delay and Exit
Tone
Procedure
The entire system can be force armed (Force Armed
All On), or just the Perimeter can be force armed
(Force Arm Perimeter Only). For this procedure, you
will force arm your system All On with Zone 1 faulted.
Since Zone 1 is faulted, its LED is on.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10
11 12 13
14 15
16
Zone 1 Faulted - LED ON
Armed Perimeter
1. Enter a valid user PIN.
2. Press the [On] key or enter [#] + [1].
3. The Status LED flashes.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10 11 12 13
14 15
16
Armed Perimeter
Flashing Status LED
Zone 1 LED ON
4. Press the [On] key again (or enter [#] + [1] again).
5. The Armed LED turns on. The Zone 1 LED now
flashes as the Exit Delay countdown begins.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10
11 12 13
14 15
16
Flashing Zone 1 LED
PerimeterArmed
Armed LED ON
When the Exit Delay countdown ends, the Zone 1
LED turns off, but the Armed LED remains on.
6. To turn the system off, enter a valid PIN.
5.10.2 Force Arming with Doubled Exit Delay and No Exit
Tone
Procedure
Using the same scenario as before (turning the
system All On with Zone 1 faulted), you will now turn
your system All On with a doubled Exit Delay and no
Exit Tone.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10
11 12 13
14 15
16
Zone 1 Faulted - LED ON
Armed Perimeter
1. Enter a valid user PIN.
2. Press and hold the [On] key (or press the [#] key
and then press and hold the [1] key).
3. The Status LED flashes and the Zone 1 LED is
on, indicating that Zone 1 is faulted.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10 11 12 13
14 15
16
Armed Perimeter
Flashing Status LED
Zone 1 LED ON
4. Press the [On] key again (or enter [#] + [1]) - do
not press and hold.
5. The Armed LED turns on and Zone 1’s LED
flashes (indicating it is being bypassed) as the
system turns on.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10
11 12 13
14 15
16
Flashing Zone 1 LED
PerimeterArmed
Armed LED ON
There is no Exit tone and the Exit Delay time is
doubled. When Exit Delay expires, Zone 1’s LED
turns off. The Armed LED stays on.
6. To turn the system off, enter a valid PIN.
The system ‘forces’ the faulted zone on. As
long as it remains faulted, it does not provide
coverage. If it returns to normal before the
system is turned off, it provides coverage and
is capable of starting an alarm event. If a zone
becomes faulted after Exit Delay begins, the
keypad displays the faulted zone. If the zone
remains faulted at the end of Exit Delay, it
starts an alarm event.
The system can be Perimeter Only-force armed and
Partial On-forced armed. To force arm the Perimeter,
use the [Perimeter Only] key (or [#] + [2]) in the above
procedures. To force arm Partial On zones, use [#] +
[3] in the above procedures.