Page 6 P/N: 49211C © 2002 Detection Systems, Inc. All rights reserved. DS7240/DS7220 User's Guide
PART I: INTRODUCTION
3.2 Keypad Tones
Both keypads (LCD and LED) emit several distinct
tones and turn on lights (LEDs) to alert you of system
events. See Table 2 for an explanation of each
keypad tone.
Keypad Tone Description
Fire Alarm When a fire zone activates, the keypad emits
a repeated tone (on for one second, then
briefly off). Enter PIN to silence.
Burglary Alarm When a burglary zone activates while your
system is turned on, the keypad emits a
continuous tone. The sounder remains on
for the duration of the time set by your
Security Company. Enter PIN to silence.
Trouble When a system component is not functioning
properly, the keypad emits a repeated tone
(on briefly, followed by a pause, followed by
on briefly, etc.). Press the [4] key to view the
trouble. If the problem is zone-related, enter
a valid user PIN and press [8] to view the
faulted zone.
Key Press Pressing any key on the keypad sounds a
short beep, indicating that the key press is
accepted.
Entry Delay When you enter the premises through a
zone programmed for Entry Delay, the
keypad emits an intermittent beep to remind
you to turn your system off. If the system is
not turned off before the Entry Delay time
expires, an alarm event occurs and a report
may be sent to your Security Company.
Exit Delay After you turn your system on, the keypad
emits an intermittent beep and counts down
the Exit Delay time. If you do not exit before
the Exit Delay time expires and an Exit
Delay zone is faulted (opening a door
specified as an Exit Delay zone), an alarm
event begins.
Error If you press an incorrect key, the keypad
emits a tone to indicate an invalid entry. The
error tone is the same tone as the Trouble
tone, but it is not repeated.
OK This tone indicates that a keypad entry is
accepted (for example, a correct PIN is
entered). The keypad emits a single, high-
pitched beep for one second.
Chime The keypad emits a tone to alert you when
any Chime zone is faulted. The tone varies
in duration depending on the Chime Tone
selected. See pages 22 and 43 for more
details.
Table 2: Keypad Tone Descriptions
3.3 Keypad LED Functions
Both keypads have four on-board LEDs that provide
visual indications of various system functions. See the
following tables for LED function descriptions.
LED State Description
On Steady System is turned All On or Perimeter
Only On with Entry Delay.
Armed
Slow Flash System is turned All On or Perimeter
Only On with no Entry Delay.
On Steady No controlled zones are faulted.
Slow Flash Key sequence function has been
entered (for example, [#]+[4]+[1] has
been entered to conduct a System
Test). PIN entry is required.
Status
Fast Flash Entry Delay timer is active.
On Steady No trouble conditions exist.
Slow Flash System Trouble exists. Keypad
roaming See “Move to Area” on page
27.
Power
Fast Flash System Testing. Last 5 minutes of
Walk Test. Another keypad is active.
Fire Fast Flash Flashes fast whenever a fire zone is
in alarm.
Table 3: DS7447i On-board LED Functions
LED State Description
On
Steady
System is turned All On or Perimeter
Only On with Entry Delay.
Armed
Slow
Flash
System is turned All On or Perimeter
Only On with no Entry Delay.
On
Steady
No controlled zones are faulted.
Slow
Flash
Key sequence function has been
entered (for example, [#]+[4]+[1] has
been entered to conduct a System
Test).
Status
Fast
Flash
PIN entry is required. Entry Delay
timer is active.
On
Steady
No trouble conditions exist.
Slow
Flash
System Trouble exists. Keypad
roaming See “Move to Area” on
page 27.
Power
Fast
Flash
System Testing. Last 5 minutes of
Walk Test. Another keypad is active.
Fire Fast
Flash
Flashes fast whenever a fire zone is
in alarm.
Trouble On
Steady
System Trouble and/or Zone Trouble
exists. Off when all trouble
conditions are cleared.
Bell
Silenced
On
Steady
Alarm has been silenced with PIN
entry. LED turns off when [#] key is
held to clear silenced alarms.
Supervisory Not used.
On
Steady
System is turned on Perimeter Only
with Entry Delay.
Perimeter
Slow
Flash
System is turned on Perimeter Only
with no Entry Delay.
Table 4: DS7445i On-board LED Functions