DS7240/DS7220 User's Guide Copyright 2002 Detection Systems, Inc. P/N: 49211C Page 43
PART II: KEYPAD USER’S GUIDE: DS7445i LED KEYPAD
5.27 Select Chime Tone
I can perform this function.
I cannot perform this function.
Key Sequence: [#] + [6] + [2]
Description
The Chime feature gives you the ability to “chime”
zones when the system is turned off. The system can
be programmed to alert you to opened doors and
windows. For example, parents with small children
may want a tone to sound whenever a door is opened
to monitor the children.
Use this function to set the type of response your
system produces when a Chime zone is faulted. See
“Select Chime Zones” to program which zones in your
system are to be chimed.
Procedure
1. Make sure that the system is turned off (Armed
LED is off).
2. Enter a valid user PIN.
3. Enter [#] + [6] + [2].
Zone LEDs 1-4 represent the four Chime Tone
selections.
Zone LED # Chime Tone
1 No Tone
2 Short Beep
3 Beep Until Key Press
4 Beep Until Closed
Table 16: Chime Tone Selections
Chime Tone Description
No Tone Displays zone(s), but no tone when
zone(s) is faulted.
Short Beep Displays zone(s) and sounds a short
tone when zone(s) is faulted.
Beep Until
Key Press
Displays zone(s) and sounds a tone
until the [#] key is pressed.
Beep Until
Closed
Displays zone(s) and sounds a tone
until the zone(s) is returned to normal
(door or window is closed). Pressing
[#] also silences the tone.
Table 17: Chime Tone Descriptions
The keypad displays the current selection by
turning its corresponding LED on and flashes the
other choices. For example, the default Chime
Tone setting is Short Beep. Therefore, the Zone
2 LED will turn on while the other three LEDs
flash.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
7 8
9 10 11 12
13 14
15 16
Armed Perimeter
Flashing Status LED
1 2 3 4 5 6
Zone 2 LED on - current Chime Tone selection.
4. Select the type of watch tone you want by
pressing the corresponding numeric key followed
by the [#] key. The keypad emits a single tone
and exits this function.
5. If you wish to only review the current setting,
press the [#] key to exit this function.
5.28 Select Chime Zones
I can perform this function.
I cannot perform this function.
Key Sequence: [#] + [6] + [3]
Description
Once you decide how your system responds to Chime
zones, you need to decide which of the zones in your
system are “chimed”.
Use this function to tell your system which zones to
chime. You cannot chime 24-hour fire and 24-hour
non-fire zones.
Choosing which zones to chime depends upon your
security objective. If you have small children, you
may choose to chime zones of entry and exit. Each
time a Chime zone is faulted (door or window is
opened), the keypad responds as programmed.
Procedure
1. Make sure that the system is turned off (Armed
LED is off).
2. Enter a valid user PIN.
3. Enter [#] + [6] + [3].
The keypad displays all zones that are currently
being chimed (Chime On).
Zone LED On: Indicates zone(s) is already
being chimed.
Zone LED Flashing: Indicates zone(s) is
available to be chimed.
On
Status
Power
Fire
Supervisory
Bell Silenced
Trouble
TEST WEEKLY
7 8
9 10
11 12 13 14
15 16
Armed Perimeter
Flashing Status LED
1 2 3 4 5 6
LEDs Flashing: Zones may be chimed.
LEDs On: Zones already being chimed.
4. To select a zone to be chimed, enter the zone
number followed by the [*] key (for example, if
you want Zone 1 to be chimed, press [1] + [*]).
5. Repeat Step 5 to select all the zones you want
chimed.
6. To turn the Chime Mode off for a zone, enter the
zone number followed by the [*] key (for example,
if you do not want Zone 5 to be chimed, press [5]
+ [*]).
7. Press the [#] key to exit this function.