6-80 Order data/reference lists Rexroth SYNAX 200
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Supply unit HMV
The supply unit
supplies IndraDrive M drive controllers with the required DC bus
voltage,
loops the 24 V control voltage of an external 24 V power supply
through to the drive,
communicates with the drive controllers via a module bus.
The supply units can be used for realizing a multitude of drive tasks in
most diverse applications.
For these purposes there are 2 different device types (regenerative, non-
regenerative) with graduated supply power available.
design with regeneration back to the mains (HMV01.1R-Wxxxx)
and without regeneration back to the mains (HMV01.1E-Wxxxx)
external 24 V supply required (signal processing not supplied from
DC bus)
external 24 V supply required (signal processing not supplied from
DC bus))
integrated mains contactor for E-Stop
integrated braking resistor (bleeder) for feeding supply units
(HMV01.1E-Wxxxx)
integrated emergency braking resistor for regenerative supply units
(HMV01.1R-Wxxxx)
Description and technical data can be found in drive documentation
"Rexroth IndraDrive - Supply Units" (DOK-INDRV*-HMV-*******-PR01-EN-
P).
1234 6789
1
05 1234 6789
2
05 1234 6789
3
05 1234 6789
4
05
Example:
Abbrev.
Column
HMV0 1 . 1 E -W0 030 - A - 07 - NNNN
1. Product
1.1 HMV . . . . . . . . . = HMV
2. Line
2.1 1 . . . . . . . . . . . . . . . . . . . = 01
3. Design
3.1 1 . . . . . . . . . . . . . . . . . . . . . . . . . = 1
4. Power supply
4.1 feeded . . . . . . . . . . . . . . . . . . . . . . = E
4.2 regenerative. . . . . . . . . . . . . . . . . . . = R
5. Cooling mode
5.1
Air, internal (through integrated blower)
= W
6. Rated output
Rated output Power supply Code
[ KW ] E R
with choke
30 X - 0030
45 - X 0045
7. Protection mode
7.1 IP 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = A
8. DC-bus nominal voltage
8.1 DC 700V. . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .= 07
9. Other design
9.1 none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = NNNN
10. Standard reference
Standard Titel Edition
DIN EN 60529 Degrees of protection provided by enclosures (IP-Code) 2000-09
DT100019V01_EN.EPS
Fig. 6-163: Type code supply unit (HMV)
Main features
Documentation supply units
Type code supply unit
Seitenansicht 255
1 2 ... 251 252 253 254 255 256 257 258 259 260 261 ... 383 384