Rexroth SYNAX 200 Motion control configuration 4-39
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Wear parts VSP 16, VSP 40
• The service life of the backlight is limited to a certain number of
operating hours. After this time the backlight will produce only 50 % of
its original brightness. This time differs for the used displays:
• 12": > 50.000 hours
• 15": > 30.000 hours
• CMOS battery: 5 to 7 years
• The hard disk is an electromechanic wear part that has to be changed
during the operating time. According to the manufacturer’s
specifications the hard disk has been developed for a service life of 60
months in consideration of the following conditions:
3,5" hard disk
Operating hours / month Max. 720
Input/output cycles / month min. 10 and max. 833
Operating conditions Temperature < 60 °C
Rel. humidity < 90 %
Height < 3000 m
Accesses 50 % of the operating hours
Storage conditions Temperature < 70 °C
Rel. humidity < 95 %
Duration < 3 months
Fig. 4-69: Typical operating and storage conditions of the hard disk
The operation out of this typical conditions is permissible, whereby,
however, the service life of the hard disk may be reduced. However,
the ambient conditions specified for the overall device have to be
absolutely kept.
• Also fans are mechanic wear components, whose service life is
extremely temperature-dependent. For the fan integrated in the
housing the manufacturer specifies the following service life:
Ambient temperature Service life
40 ° C 70 000 hours
70 ° C 35 000 hours
Fig. 4-70: Service life of the fan
Wear parts that are without
guarantee