4-34 Motion control configuration Rexroth SYNAX 200
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Specifications of the power supply 115V / 230V
Nominal input voltage: 115 VAC / 230 VAC
Input voltage range: 85 ...264 VAC
Input current:
1,0 A at nominal voltage 230 VAC
2,0 A at nominal voltage 115 VAC
Max. switch-on current
(cold start 25
° C)
40 A at nominal voltage 230 VAC
20 A at nominal voltage 115 VAC
Output voltage:
+5 V
+12 V
-12 V
+20 V
ISO 6V
current (max.)*
20 A
3 A
500 mA
2 A
200 mA
tolerance (incl. rest ripple)
+/-5 %
+/-5 %
+/-5 %
+/-5 %
+/-5 %
Max. output power:
160 W*
Efficiency:
0,8
*) Note: At the specification of the maximum output currents it must be noticed that these
values are the maximum possible currents from the respective output voltage. But the
maximum current cannot be extracted from all output voltages at the same time, because
the maximum sum of output power that has an amount of 160 W, may not be exceeded.
Fig. 4-58: Specifications of the power supply 115V / 230V
Specifications of the power supply 24V
Nominal input voltage: 24 VDC
Input voltage range: 24 VDC +20%, -15%
Noise and surge immunity
Umax = 35 V (for t < 100 ms)
Max. input current:
6 A at nominal voltage 24 V
Max. switch-on current
25 A at nominal voltage 24 V
Output voltage:
+5 V
+12 V
+24 V
-12 V
ISO 6VV
current (max.)*
+5 V
+12 V
+24 V
-12 V
ISO 6V
tolerance (incl. rest ripple)
+/-5 %
+/-5 %
+/-5 %
+/-5 %
+/-5 %
Max. output power:
110 W*
Efficiency:
0,8
*) Note: At the specification of the maximum output currents it must be noticed that these
values are the maximum possible currents from the respective output voltage. But the
maximum current cannot be extracted from all output voltages at the same time, because
the maximum sum of output power that has an amount of 110 W, may not be exceeded.
Fig. 4-59: Specifications of the power supply 24 V