Rexroth SYNAX 200 Motion control configuration 4-25
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Digital inputs and outputs of the PPC-R2x
3 digital inputs
(potential-free)
"0" signal: input voltage –3V.. 5V;
input current ≤ 2,5mA
"1" signal: input voltage 11V..30V;
input current 2,8mA ≤ I ≤ 6mA
delay: typ. 100µs
2 digital outputs
(potential-free)
output voltage 24V;
output current 0,5A (nominal value), short-circuit-proof
"1" signal: 2mA ... 0,6A; voltage drop ≤ 1,5V
"0" signal: leakage current ≤ 0,5mA
delay: < 500µs
1 Bb – relay (ready for operation)
(system monitoring)
NO contact
V
n
= 24 V
DC
, I
max
= 150 mA
min. 500 000 switch cycles (overcurrent protected)
Fig. 4-39: Inputs and outputs of the PPC-R2x
EMC of the PPC-R2x
Emitted interference to EN 55022 Class A (industrial environment)
Noise immunity to EN 61000-4-2 (ESD) Rating criterion B
Noise immunity to EN 61000-4-4 (Burst) Rating criterion B
Noise immunity to EN 61000-5-5 (Surge) Rating criterion B
Fig. 4-40: EMC data of the PPC-R2x
DERATING I/O bus supply
0 – 35 °C 100 % (52 W)
35 – 45°C 85 % (44 W)
Fig. 4-41: DERATING I/O bus supply
Interfaces of the PPC-R2x
Programming interface (PROG) RS232/RS422/RS485 w/o RS232 control signals (D-SUB, 15-way
female connector), electrically isolated
General serial interface (COM) RS232/RS422/RS485 with RS232 control signals (D-SUB, 15-way
female connector), not electrically isolated
Ethernet interface (optional) RJ45 female connector 10/100 BASE-TX
Fig. 4-42: Interface specifications of the PPC-R2x