Rexroth SYNAX 200 Motion control configuration 4-17
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
4.11 Installation instructions RECO control
The module carriers must first be installed before the PPC-R units can be
installed. These module carriers are equipped with the PPC-R unit and,
according to the requirements, with the related I/O modules (RECO02
modules).
Installing the module carriers
To install the module carrier RMB02.2-04, you must latch it onto a DIN rail
TS 35x27x15 and secure it with a retaining screw. The module carrier
may also be installed directly on the installation plate in the control
cabinet. This is done through boreholes provided in the module carrier.
Up to four RMB02.2-04 module carriers can be installed side-by-side. The
PPC-R must be in slot 0, if it shall be able to control the RECO bus. Slot
addressing requires the DIP switch on the bus board of the RMB02.2-04
module carrier to be configured.
Note: The installation position of the module carrier must be made in
such a way, that the PPC-R is in vertical position. The supply-
and exhaust air openings of the housing must be kept free.
Arrangement of the module carrier
4x RMB02.2-04
with a total of 16 module slots for
accommodating the PPC-R and
different I/O modules
YG000044V01_EN.FH7
Fig. 4-28: Maximum configuration RMB02.2-04