9-38 Appendix Rexroth SYNAX 200
DOK-SYNAX*-SY*-12VRS**-PR01-EN-P
Option L1: Starting lockout
DA100005V01_NN.FH7
1
5
6
9
Fig. 9-61: L1 - D-Sub socket
Meaning Signal Pin
Controlling signal for starting lockout assignment A AS-A 1
Inverted controlling signal for starting lockout ASn 2
Controlling signal for starting lockout assignment B AS-B 3
Supply for acknowledgment potential ASQ 4
Acknowledgment ASQ1 5
Inverted acknowledgment ASQ2 6
not used - 7
24 V supply voltage +24 V
E
8
Reference potential of the 24 V supply voltage 0V
E
9
Fig. 9-62: L1 - D-Sub socket - connection assignment
Option S1: Safety technology I/O
DA100005V01_NN.FH7
1
5
6
9
Fig. 9-63: S1 - D-Sub socket
Meaning Signal Pin
Input/output for forced dynamization EA30 1
Input/output for acknowledgment EA20 2
Input/output for diagnostic message/safety door locking device EA10n 3
E1n 4
E2n 5
E3n 6
Inputs for operating mode selection
E4n 7
24 V supply voltage +24V
E
8
Reference potential of the 24 V supply voltage 0 V
E
9
Fig. 9-64: S1 - D-Sub socket - connection assignment