Bosch PIF6..T1.. Spezifikationen Seite 46

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 45
ECODRIVE Drive Controller DKC02.1
4-14 Command Diagnostic Messages DOK-ECODRV-SSE-03VRS**-WAR1-EN-P 12.96
D400 Positive stop drive procedure command
When the command "travel to dead stop" is activated, all controller
monitoring functions are de-activated that would cause a class 1
diagnostics message to be issued when the drive is blocked by a dead
stop.
Cause:
The command D400 Positive stop drive procedure command has
been activated.
D401 ZKL1 Error at Command Start
Cause:
A class 1 diagnostics error has been detected when the command "travel
to dead stop" was activated. The command could therefore not be
executed.
Remedial action:
Eliminate the cause of the reported error. Clear the error and start the
command again.
Seitenansicht 45