
D7212GV2 | Program Entry Guide | 5.0 RADXSKED EN | 109
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
S## Area 1[through 4]
Yes
Unbypass all
points in Area
#.
5
Unbypass All Points: This function
is not available as a keypad function.
The entry in the
S## Area #
prompt
defines the area(s) where the sked
unbypasses all points. The sked
unbypasses all points in the area,
regardless of how they were
bypassed. This sked can unbypass all
points in multiple areas.
Default: No
Selection: Yes or No
Select Yes to unbypass all
points in the areas indicated.
No Do not
unbypass all
points in
Area #.
S## Relay Number
Blank
No relay is
activated.
6
Relay On: This function emulates the
Chg Relay keypad function to turn
relays on. The entry in the
S##
Relay Number
prompt defines the
specific relay this sked activates. The
sked can activate one relay.
Default: Blank
Selections: Blank,
1 to 24
Enter the number of the relay
the sked activates
1 to 24
Relay to
activate.
S## Relay Number
Blank
No relay is
turned off.
7
Relay Off: This function emulates the
Chg Relay? keypad function to turn
relays off. The entry in the
S##
Relay Number
prompt defines the
relay this sked turns off. The sked can
turn off only relays that are set by a
sked. The sked can turn off one relay.
Default: Blank
Selections: Blank,
1 to 24
Enter the number of the relay
that turns the sked off.
1 to 24
Relay to turn
off.
8 All Relays Off: This function is not available as a keypad function. This sked function turns off all relays
that are turned on by a sked. This is a panel-wide function.
No other parameters require input for this option.
Kommentare zu diesen Handbüchern