D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 31
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
The control panel tries to contact RPS only
once using this method.
Refer to Section 6.4 SDI RPS Parameters on page 118 for
other connection methods.
2.8 Miscellaneous
Duress Type
Default: 0
Selection:
0, 1, 2, or 3
0 Do not send a duress event with any passcode.
1 Increase the last digit by 1 to generate an alarm.
For example, if the passcode is 6123, 6124
activates a duress alarm.
If the last digit of the passcode is 0, a duress
alarm occurs when the user enters 1 as the last
digit of the passcode.
If the last digit of the passcode is 9, a duress
alarm occurs when the user enters 0 as the last
digit of the passcode.
2 Increase the last digit by 2 to generate an alarm.
For example, if the passcode is 6123, 6125
activates a duress alarm.
If the last digit of the passcode is 8, a duress
alarm occurs when the user enters 0 as the last
digit of the passcode.
If the last digit of the passcode is 9, a duress
alarm occurs when the user enters 1 as the last
digit of the passcode.
3 Send a Duress event when any Passcode with
L# Send Duress
set to Yes is entered.
This program item determines if users add one (+1) or
two (+2) to the last digit of the passcode. To activate a
duress alarm, the user increases the value of the last
digit of the passcode when entering it at the keypad.
Duress is enabled in Area Parameters by
setting A# Duress Enable to Yes.
The duress alarm activates when a user
enters the duress passcode followed by the
termination keys ([ESC] or [ENT]).
For SIA CP-01 Compliance
Duress Type
must be set to 3.
Cancel Report
Default: No
Selection:
Yes or No
Yes Send Cancel and Fire Cancel Reports
according to routing.
No Do not send Cancel and Fire Cancel
Reports.
A Cancel and Fire Cancel Report is created when a
passcode is entered to silence an Alarm Bell or a Fire
Bell before the bell time expires.
For SIA CP-01 Compliance
This prompt must be set to Yes.
2.9 Area Parameters
This programming module contains three
programming categories: Area Parameters, Bell
Parameters, and Open/Close Options.
2.9.1 Area Parameters
Area
Default: 1
Selection:
1 to 4
Enter the area number you are programming.