When the first digit of the second code is pressed, the
following message appears. As each digit is pressed, an
additional asterisk appears.
A# Early Ambush
Default: No
Selection:
Yes or No
Yes Two valid passcodes are required to
disarm the area within the time period
specified in Early Ambush Timer. The
second valid disarm passcode must be
entered within a time limit. Refer to
Early Ambush Timer on page 130.
If the second passcode is not entered
within the time limit, the system
generates a Duress Event based upon
the primary user.
No A single passcode with a valid
authority level can disarm the area.
The
Early Ambush
disarming feature is intended for
use when you disarm an area that is in the Master
Armed state, but it can also be used with the Perimeter
and Instant Armed states. After the first valid passcode
is entered, the area is disarmed and the keypad
displays the disarmed idle text normally. This function
operates only when you use Passcode Disarm.
If the second valid disarm passcode is entered, the
D1255 Keypad shows CODE 2 VALIDATE and
sounds the Watch Mode tone. Only the Watch Mode
tone appears on the D720 Keypad.
The D1260 Keypad sounds the Watch Mode tone and
the following text appears.
Parameter Setup Requirement:
The Early Ambush timer can be started and stopped
only by passcodes with the L## Passcode Disarm
authority.
To avoid unintended results for the end
user of the system:
When a keypad is assigned to an area
that has the Early Ambush feature
enabled, set the CC# Scope value to
Area Wide.
If an area has A# Two Man Rule set to
Yes, do not set A# Early Ambush to
Yes.
During an alarm, after the first passcode is entered, the
Early Ambush timer still begins. A Cancel Report
might be generated, depending upon the bell time, and
the keypad displays Alarm Silenced normally. If
the second valid disarm passcode is entered, the
keypads indicate that the second passcode is valid.
Refer to the
Secondary Ambush Code
prompt on
page 130 for information about the unique behavior of
the two passcodes.
For SIA CP-01 Compliance:
This feature is not allowed in SIA CP-01
compliant installations.
A# Exit Restart
Default: Yes
Selection:
Yes or No
Yes Delay armed points in this area restart
the exit delay timer if violated during
the exit delay time.
No Delay armed points continue to count
down normally if violated during the
exit delay time.
This feature must be disabled for UL Line
Security/Encryption applications.