D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 48
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
CC# Scope
Default: Refer to the program record sheet
Selection:
Panel Wide, Custom, No Keypad,
Area, and Account
Panel
Wide
A panel-wide keypad can view
information and perform Arming and
Disarming functions for all areas in the
control panel. A panel-wide keypad
can cross account boundaries. This is
normally used with a master area.
Account An Account keypad can view
information, and perform Arming and
Disarming functions for all areas with
the same
A# Acct Number
, in Area
Parameters. This is normally used for
an associate area.
Area An area keypad is restricted to viewing
information and Arming or Disarming
functions for the area to which it is
assigned.
Custom A custom keypad has no keypad
restrictions.
No
Keypad
No keypad installed at this address.
CALL FOR SERVICE display shows,
indicating the control panel is not
polling this address.
This program item is used to define the areas affected
when an arming command is executed on this keypad,
the areas this keypad can view, and the areas to which
this keypad can move.
Press the [SPACE] bar to scroll through the selections.
Press [ENTER] when the correct selection appears in
the display.
In applications where keypads include more
than one area, active alarms in remote
areas must be acknowledged before
arming or disarming the local area.
The following prompt is visible only when
you program CC## Scope to Custom. If
you change the keypad scope selection to
Custom from Panel Wide, Account, or
Area, the settings from the previous CC#
Scope selection become the default
settings for the custom parameters in CC#
A1 [through A4] in Scope. Before exiting a
custom program, check each area and
ensure that it is enabled and disabled
correctly.
CC# A1[through A4] in Scope
Default: Refer to the preceding important
note
Selection:
Yes or No
Yes Include this area in the scope of this
keypad.
No Do not include this area in the scope
of this keypad.
Determines whether any of the four areas (Area 1 to
Area 4) are included in the scope of this keypad for
viewing status and arming or disarming the keypad.
The D7212GV2 allows programming for
Areas 1 through 4 only.
The D5200 Programmer allows entries
for Areas 5 through 8, but they cannot be
used on the D7212GV2.
If Areas 5 through 8 are programmed for
the D7212GV2, the keypad displays
CALL FOR SERVICE.
CC# Entr Key Rly
Default: Blank
Selection:
1 to 24, A, B, C, and Blank
Blank The [ENTER] key is not used to
activate a relay.
1 to 24, A,
B, C
Assign the relay number that activates
when [ENTER] is pressed at this
keypad after the user enters a valid
passcode.
Enter Key Relay: Program the relay number that
activates momentarily for 10 sec when a user enters a
valid passcode and presses the [ENTER] key on the
keypad. Two events are generated when this function
is used: RELAY ### SET with User ID, and RELAY
### RESET without User ID. The system logs this
action as two events.
Entering a valid code and pressing [ENTER] silences a
ringing bell.
When programmed to activate a relay, the
[ENTER] key cannot be used for any other
function.
Relays used for this function must not be
shared with any other point, sensor reset,
control panel, or bell functions. Sharing can
cause errors in relay operation.