D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 63
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
L## Perim Delay
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
5 Perimeter Delay
Arm
[COMMAND][3]
Delay arm all Perimeter Delay point responses only in
the area where the keypad is assigned.
L## Watch Mode
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
6 Watch Mode [COMMAND][6]
Initiate the Watch Mode in the area to which this
keypad is assigned.
L## Perim Partial
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
7 Perimeter Partial
Arm
[COMMAND][8]
Partially arms only the area where the keypad is
assigned.
This function ignores the A# FA Bypass
Max entry in Area Parameters.
Local Only Reporting: No Closing Report
is sent to the central station, but a
Perimeter Delay Closing Event is generated
in the event log.
L## View Area Stat
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
8 View Area Status (Menu function only)
View the current arm or disarm status and the not
ready to arm status of all areas within the scope of the
keypad in this area. The user needs arming and
disarming authority.
L## View Memory
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
9 View Event
Memory
[COMMAND][4][0]
View all memory events that occurred since the last
time the system was armed for all areas within the
scope of the keypad in this area.
L## View Pt Status
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
10 View Point Status (Menu function only)
View the current status of all points in the area to
which this keypad is assigned.
L## Walk Test
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
11 Walk Test [COMMAND][4][4]
Walk Test all Interior or Perimeter Controlled points
in the area to which this keypad is assigned.
The following features come with the Walk Test
Mode:
Battery powered control panel only. A Battery
Test runs during the whole test to ensure that the
battery capacity is capable of supporting the full
load of the control panel if AC fails.
- This test includes two-sec Bell Test when the
Walk Test starts.
- The test ends when all points are tested or the
test times out after 20 min of no activity.
Local alarm annunciation and event printing; no
reports are sent to the central station receiver.
D1255 Keypad displays a sequential count, and
text after each point is activated and restored.
The keypad displays ALL PTS TESTED and an
All Points Tested Event is sent to the central
station receiver (if programmed) when the last
point is tested.