6.0 GV2AUX
6.1 Introduction
The GV2AUX Handler is used primarily for
programming Enhanced Communication capabilities
for the 9000GV2 Series Control Panels.
“Enhanced communications” represents the ability to
provide new communication functions for the control
panels using the SDI bus including:
• Routing control panel events to a network
interface module (NIM).
A network interface module (NIM) can be a
D9133TTL-E or a DX4020.
• Communicating with remote programming
software (RPS) using a network interface module
(NIM).
• Communicating with a remote or local automatic
software package.
6.2 RPS and D5200 Handler
Requirements
In order to program the GV2AUX parameters for the
control panels, you must use RPS version 3.8 or higher
and a handler called GV2AUX. To add the GV2AUX
Handler to your D5200 Programmer, call the Bosch
Security Systems, Inc. Handler Update System at
(800) 657-4584.
This handler currently has six sections:
• SDI Automation
• SDI RPS Parameters
• Enhanced Communications
• SDI RPS/Enhanced Communication
Configuration
• Miscellaneous
• Cross Point Parameters
The handler required for these options is GV2AUX
version 1.0 and above. It is available on the Handler
Update System at Bosch Security Systems, Inc..
6.3 SDI Automation
SDI automation defines the characteristics of a serial
interface module (SIM) when used with home or
business automation software. The SIM is a two-way
SDI to serial communication module that allows the
control panels to send and receive information to and
from an external software program.
The SIM can be a D9133, DX4010i, or
DX4020 (configured to emulate serial
communication).
This automation protocol allows external software
programs to interact and perform functions such as:
• arming and disarming areas,
• changing user passcodes and names, and
• turning relays on and off.
The items described in this section allow some simple
configuration options. To receive the SIM automation
protocol; however, you must contact Bosch Security
Systems, Inc. Technical Support at (888) 886-6189.
Enable SDI Auto
Default: No
Selection: Yes or No
Yes Enable Automation software.
No Disable Automation software.
Changing this item to Yes enables the automation
address (SDI Address 80).
Baud Rate
Default: 9600
Selection: 300, 1200, 2400, 4800, 9600, 14.4 K
This item determines the baud rate between the serial
interface module (SIM) and the external hardware
connected to it. Since the SDI bus communicates at
9600 baud, keep this prompt at 9600 baud. Pressing
the [SPACE] bar on the D5200 toggles through the
available options.