D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 44
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
• To suppress reports immediately after midnight,
use another window (for example, 00:01 start to
02:00 stop).
2.9.6 Arming Features
A# Two Man Rule
Default: No
Selection:
Yes or No
Yes Two valid unique passcodes are
required to disarm the area.
No A single passcode with a valid
authority level can disarm the area.
The D720 Keypad does not support the
Two-Man Rule feature.
Use this parameter when disarming an area that is
Master Armed. After recognizing the first valid
passcode, the system requests a second passcode to
disarm the area. If the entry delay expires before the
entry of a second valid unique passcode, an alarm
condition occurs. This function works only when you
use Passcode Disarm.
When you are disarming an area with A#
Two Man Rule set to Yes, the keypad
waits for the time equal to the A# Exit
Delay Time. If the second passcode is not
entered before the prompt times out, the
rule resets and waits for the first passcode
again.
If the area is already in an alarm condition,
the first valid passcode entered after the
alarm occurs silences the bell but does not
disarm the area. Enter Code 2 appears
on the display. A second valid unique
passcode is necessary to disarm the area.
This feature is not allowed for use with
SIA CP-01 compliant installations. Consult
the local authority having jurisdiction (AHJ)
for proper usage.
Parameter Setup Requirement:
Two Man Rule can be completed only by entering two
valid unique passcodes with
L## Passcode Disarm
authority.
To avoid unintended results for the end
user of the system:
• Set CC# Scope to Area Wide for
keypads assigned to areas with the
Two Man Rule feature.
• Avoid setting the A# Two Man Rule to
Yes in an area where A# Early
Ambush is set to Yes.
Use this feature in banks or other facilities
that might require a higher level of security
to gain access to a vault or other protected
area.
D1255 Keypad
After the first valid passcode is entered, the D1255
replaces the scrolling DISARM NOW and the Point Text
display with the SECOND CODE:.display
When the user presses the first digit of the second
code, the display changes to SECOND CODE: *.
SECOND CODE: appears for ten sec. If no digits are
pressed, the display returns to normal and the area
does not disarm. If a second code is entered, the area
disarms and an Opening report is sent with the User
ID of the first user. If the second code entered is the
same as the first code, is invalid, or does not have
L##
Disarm
authority, the keypad shows NO AUTHORITY
and returns to idle text or entry delay.
D1260 Keypad
In the D1260, after the first valid passcode is entered,
the following message appears for three sec.
Then the next message appears requesting a second
code.