D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 72
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
A# Reset Sensors
Default: C
Selection: Blank, 1 to 24, A, B, or C
Unlike the default relay for Alarm Bell and Fire Bell,
this voltage-output relay (Relay C) de-activates for 5
sec when the Reset Sensors? function is activated
from the keypad or during a Fire Walk Test.
The Reset Sensors time converts from the
5 sec default time to the time programmed
in A# Verify Time (Section 2.9 Area
Parameters on page 5) when a point
programmed for P## Alarm Verify
(Section 4.1 Point Index on page 80)
enters an alarm condition.
When sharing one relay to reset sensors in
two or more areas, you must program the
following. Failure to do so causes
TROUBLE PT ### for all point types
programmed as P## Resettable.
• CC # Scope must include all areas that
share the relay.
• L## Reset Sensors authority must be
assigned to the passcode that activates
the COMMAND 47 or Reset Sensor
function.
• A# Verify Time must be the same
number of seconds for all areas that
share the relay.
A# Fail to Close
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
This relay activates when the Closing Window expires
for the specified area. It remains active until midnight,
another Closing Window starts, or the control panel
resets, whichever occurs first. When
Perimeter Relay
(refer to page 131) is set to Yes, the
A# Fail to Close
prompt becomes
A# Perimeter Relay
when using
firmware version 7.07 and later. Refer to Area 7 in
Alternate Functions for A# Silent Alarm on page 73 for
additional relay functions when using firmware version
7.06 and earlier.
A# Force Armed
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
This relay activates when this area is Force Armed. It
remains active until the area disarms or the control
panel resets.
If Force Bypassing is required during
Perimeter Arming, this relay does not
activate.
A# Watch Mode
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
This relay activates when a Controlled point
programmed for
P## Watch Point
is faulted in the
specified area while the area is in Watch Mode and the
point is not armed. It remains active for 2 sec after
each point is faulted.
A# Area Armed
Default: Blank
Selection: Blank, 1 to 24, A, B, or C
This relay activates when the specified area becomes
Master Armed. The exit delay must expire before the
relay activates. The relay remains active until the area
disarms. It does not deactivate during the entry delay
time.
If multiple areas use the same relay, the relay activates
when all areas are armed. It deactivates when the first
area disarms.
The
A# Area Armed
relay function can provide
visual feedback at a key switch station. Attach a LED
to the output of a D8129 Module programmed for this
function.
Refer to Area 7 and Area 8 in Alternate Functions for A#
Silent Alarm on page 73 for additional relay functions
when using firmware version 7.06 and earlier.