D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 60
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Bypass a Pt
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
25 Bypass a Point [COMMAND][0]
Use this function to bypass individual points that have
P## Bypassable
enabled. Points within the scope of
the keypad can be bypassed where the function is
entered (refer to Section 2.10.1 Keypad (Command Center)
Assignment) on page 46.
The control panel ignores alarms and troubles, and
does not display point faults when a point is bypassed.
Unbypass a Pt
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
26 Unbypass a Point [COMMAND][0][0]
Use this function to unbypass individual points that are
programmed either
P## FA Retrnable
or
P##
Bypass Returnable
. Points within the scope of the
keypad can be unbypassed where the function is
entered (refer to Section 2.10.1 Keypad (Command Center)
Assignment) on page 46. The control panel responds to
alarms and troubles, and displays point faults when a
point is unbypassed.
Reset Sensors
Default: E
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
27 Reset Sensors [COMMAND][4][7]
Use this function to activate the Reset Sensors function
for Fire or Intrusion points programmed as
P##
Resettable
in Section 4.1 Point Index on page 80. Points
within the scope of the keypad where the function is
entered reset. Refer to Section 2.10.1 Keypad (Command
Center) Assignment on page 46.
Change Relay
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
28 Change Relays [COMMAND][5][4]
Use this function to manually set and reset Relays 1
through 24 that are installed in the system.
Remote Program
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
29 Remote
Programming
[COMMAND][4][3]
Use this function to start remote programming
software (RPS) sessions. When the phone is ringing at
the control panel, starting this function causes the
control panel to seize the line.
Move to Area
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
30 Move to Area [COMMAND][5][0]
Use this function to switch the keypad’s assignment
temporarily to a different area. This command can be
used to perform any function that can be performed
by a keypad assigned to the area in programming.
Users are limited to performing functions enabled by
the authority level they have in the area to which the
keypad is moved. After 15 sec of no activity at the
keypad, the keypad reverts back to the originally
programmed area.
Display Rev
Default: E
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
32 Display Software
Revision
[COMMAND][5][9]
Use this function to show the control panel’s software
revision number in the keypad display.