2.0 GV2MAIN
Use GV2MAIN programming module to define the
operating characteristics that affect panel-wide
functions. This module has nine programming
categories:
Phone
Phone Parameters
Routing
Enhanced Communications
Area Parameters
Keypad
User Interface
Function List
Relay Parameters.
2.1 Phone
The control panel can dial as many as four different
telephone numbers when sending event reports. All
telephone numbers use the same receiver format. Refer
to Section 2.3 Routing on page 12. For information about
event report routing and communication protocols.
Phone 1
Default: Blank
Selection:
Up to 24 characters (do not enter
[SPACE])
0 to 9 Numbers 0 through 9
C Three-sec pause
D Seven-sec dial-tone detection
# or * Used for the same purpose as pressing
this key on a telephone keypad when
manually dialing. For example, an
asterisk (*) may be needed to access
your long distance service. Do not use
these characters when pulse dialing.
Blank Control panel dials no phone number.
Programming this item Blank does not
disable phone routing. To disable
reporting to this phone, refer to Section
2.3 Routing on page 12.
This is the telephone number the control panel dials to
contact the central station receiver when sending event
reports. This number is Phone 1 referred to in the
prompts in Section 2.3 Routing on page 12.
The control panel is programmed with a seven-sec dial
tone detect period. When a dial tone is detected or the
waiting period ends, the control panel begins to dial.
To extend the dial tone detect period, place a D before
the phone number. To insert a pause during or after
dialing, use C in the number sequence. For example, if
the control panel hangs up before it hears the Modem
IIIa
2
Ack tone from the D6500/D6600, program extra
Cs after the phone number. The control panel waits on
line for three extra seconds for each C programmed.
Enter up to 24 of the characters shown in the
Phone 1
table to define dialing characteristics.
Using both phone-data entry lines: The first
line of the phone number data entry line
must be filled (twelve characters) before
you press [ENTER] to move to the second
line. If you enter characters on the second
line, and the first line has less than twelve
characters, the second line clears when
you press [ENTER].
For SIA CP-01 Compliance
Call Waiting Disable
If the telephone system at the installation site uses the
Call Waiting feature, ensure that the backup telephone
reporting number is programmed to disable Call
Waiting.
If you program the primary phone number with a
sequence to temporarily disable Call Waiting (typically
*70 pause, but verify with the phone service provider)
followed by the phone number, you should program
the backup phone number without the Call Waiting
cancel sequence. If the subscriber cancels Call Waiting
without notifying their alarm installing company, the
control panel can still send reports using the backup
number.
Dialing a Call Waiting sequence on a non-
Call Waiting line prevents the system from
dialing the central station receiver
successfully.
Example: If the central station telephone
number is 555-1234, and the backup
Route Group destination is Phone 2,
program Phone 2 with the following
sequence: 70C5551234.