Bosch PIN8 N1 Anleitung zur Fehlerbehebung Seite 164

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 728
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 163
5-40 Motor, Mechanical Axis System, Measuring Systems MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
For asynchronous motors the value for P-0-0534 is determined by:
40430P05340P =
P-0-0534: voltage loop integral action time (in ms)
P-0-4043: rotor time constant (in ms), see p.5-40
Fig. 5-46: Calculating the value for P-0-0534 for asynchronous motors
The parameter P-0-0535, Motor voltage at no load takes effect in field
weakening operation.
value to be set is "80" (in %)
Note: For linear motors this parameter is irrelevant. Its default value
mustnt be changed!
The parameter P-0-0536, Motor voltage max. takes effect in field
weakening operation.
value to be set is "90" (in %)
Note: For linear motors this parameter is irrelevant. Its default value
mustnt be changed!
Determining Other Parameter Values only Relevant for
Asynchronous Motors
The value for parameter P-0-4004, Magnetizing current is the rms value
of the motor magnetizing current.
Mag
I40040P =
P-0-4004: magnetizing current (rms value in A)
I
Mag
: indicated magnetizing current (rms value in A)
Fig. 5-47: Calculating the value for P-0-4004
If there hasnt any value been indicated in the output data of the
asynchronous motor, the following approximation can be used for
calculation:
Nenn
2
I)(cos140040P =
ϕ
P-0-4004: magnetizing current (rms value in A)
I
Nenn
: rated current of the motor (rms value in A)
cos ϕ: power factor at rated load
Fig. 5-48: Calculating the value for P-0-4004 by means of approximation
The parameter P-0-0532, Premagnetization factor influences the value
of the no-load current (magnetizing current). This value indicates how
many percent of the magnetizing current are flowing when the motor has
no load.
The following values are recommended:
Drive application Value for P-0-0532
servo application 100
spindle application 50
Fig. 5-49: Recommended values for the premagnetization factor
This parameter determines to which degree the slip in the motor is
increased depending on the temperature rise of the motor windings. The
P-0-0535, Motor voltage at no
load
P-0-0536, Motor voltage max.
P-0-4004, Magnetizing current
P-0-0532, Premagnetization
factor
P-0-0530, Slip increase