9-6 Extended Drive Functions MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
By registering a measured value trigger within the "expectation
window" the value in parameter P-0-0224, Probe, number of marker
failures is cleared.
Note: The "expectation window" cannot be used with "time
measurement"!
The limitation values for the "expectation window" are set in the following
parameters:
P-0-0204, Start position for active probe
P-0-0205, End position for active probe
The "expectation window" has to cover a minimum range so that at least
on actual position value generation can take place within the window after
the probe signal edge has been detected:
tvPPs =
maxmin
)02040()02050(
s
min
: minimum value of "expectation window"
P-0-0204: start position for active probe
P-0-0205: end position for active probe
v
max
: maximum velocity of the axis with activated measured value
detection (select time reference of v-unit as tunit!)
t: 0.5*10
-3
s for basic performance (see P-0-0556)
0.25*10
-3
s for advanced performance (see P-0-0556)
Fig. 9-2: Determining the minimum value for the "expectation window"
In the case of modulo scaling of the position data, a maximum value for
the "expectation window" mustnt be exceeded as otherwise it exceeds
the modulo value range and therefore is without effect:
minmax
)01030( sSs =
s
max
: maximum value of "expectation window"
s
min
: minimum value of "expectation window"
S-0-0103: modulo value
Fig. 9-3: Determining the maximum value for the "expectation window"
Notes on Commissioning
Make the following settings in S-0-0169, Probe control parameter:
evaluation of probe signal edge as measured value trigger
select enabling mode of probe (single measurement or continuous
measurement)
Make further settings in P-0-0226, Probe, extended control word:
activation of expectation window and failure monitor
activation of time measurement
probe selection
Select measuring signals from S-0-0428, Probe, IDN list signal
selection; enter the selected parameters in:
S-0-0426, Signal select probe 1
S-0-0427, Signal select probe 2
Setting the Expectation Window
Presettings