MPH-02, MPB-02, MPD-02 Extended Drive Functions 9-43
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Pertinent Parameters
• S-0-0398, IDN list of configurable data in signal status word
• S-0-0399, IDN list of configurable data in the signal control word
• P-0-0300, Digital I/Os, assignment list
• P-0-0301, Digital I/Os, bit numbers
• P-0-0302, Digital I/Os, direction
• P-0-0303, Digital I/Os, status display
Pertinent Diagnostic Messages
• C0246 Trav. range lim. switch not ass. to dig. input
• C0247 Dig. output already assigned to another axis
• C0248 Dig. input assigned differently to axes
• C0249 Dig. I/Os: bit number too large
• F2010 Error when init. digital inputs/outputs
• F2033 External power supply X10 error
Digital Inputs/Outputs on Optional Module MD1
It is possible to individually configure a digital I/O extension for the
configurable advanced control sections.
The optional module MD1 can be used for the following purposes:
• making available digital I/Os for external control unit
• enabling input/output of drive parameters
• making available digital I/Os for drive-integrated PLC
(IndraMotion MLD-S)
• extension of memory (32 kB non-volatile memory) for drive-integrated
PLC
Note: Utilization of digital I/O extension by using the optional module
MD1 is only possible for advanced control sections!
• connection via 25-pin D-Sub connector
• all inputs/outputs (except for the relay contact) designed for level of
0 V (LOW) or 24 V (HIGH)
• separate 24 V supply of the digital outputs
• inputs/outputs galvanically isolated
• assignment of inputs/outputs to internal parameters or bits
• parameters P-0-0081 and P-0-0082 can be completely assigned to
parameters of the drive or of the integrated PLC
• free configuration of the digital inputs/outputs via S-0-0144, Signal
status word and S-0-0145, Signal control word
• 12 digital inputs (freely configurable and protected from reverse
polarity)
• 8 digital outputs (max. output current 0.5 A and sustained short-circuit-
proof)
Features