4-24 Master Communication MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Note: The data for the field bus status word refer to the I/O mode
with block acknowledgment (default configuration).
Notes on Parameterization/Commissioning
The following settings are made in the I/O mode as default setting:
• Fixed real-time channel length of 2 bytes. Thus the length of the cyclic
data channel is (P-0-4082 = P-0-4071 = 2)!
• Bits 0...5 of P-0-4051, Positioning block acknowledgment are
copied to bits 8...13 of S-0-0144, Signal status word.
• In the real-time channel only P-0-4068, Field bus: control word IO
and S-0-0144, Signal status word are transmitted.
Note: With this profile selection, the functional compatibility to the
DKC3.1 drive controllers is established!
Control units that process the real-time data in Motorola format
have the high byte and low byte interchanged compared to the
DKC3.1!
There are the following possibilities for free configuration/expansion:
• The user can freely expand the length of cyclic data channel P-0-4082
or P-0-4071 up to a maximum of 9 words. Apart from the control and
status word, further real-time data can be configured via the
parameters P-0-4080, Field bus: config. list of cyclic actual value
data ch. and P-0-4081, Field bus: config. list of cyclic command
value data ch..
• The content of S-0-0144, Signal status word can be freely
parameterized via S-0-0026, Configuration list signal status word
and S-0-0328, Assign list signal status word.
Freely Configurable Mode (Rexroth Profile Type)
Brief Description
To use the extensive and numerous functions of a Rexroth drive with field
bus interface it is necessary, in addition to the I/O mode (downwards
compatible to the DKC3.1), to define another profile, the freely
configurable mode. This implies the use of a new controls and status
word (P-0-4077, Field bus: control word and P-0-4078, Field bus:
status word).
• The structure (content) of the real-time data channel must be defined
via the configuration parameters P-0-4080 and P-0-4081. No profile-
dependent settings and checks are carried out!
• In this profile type the Rexroth-specific definitions for the field bus
control and status words apply. Some bits in the parameters P-0-4077,
Field bus: control word and P-0-4078, Field bus: status word can
only be used in conjunction with certain operating modes.
• This profile type allows using the entire drive functionalities (e.g.
velocity synchronization, drive-controlled positioning, ...).
• The primary and secondary modes of operation can be freely selected
via S-0-0032, S-0-0033, S-0-0034 and S-0-0035.
Features with Default
Configuration
Features and Settings with Free
Configuration or Expansion
Features