MPH-02, MPB-02, MPD-02 Operating Modes 7-125
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Via parameter P-0-0089 (bit 0,1) there is a feedback indicating which cam
shaft is presently active.
P-0-0089, Status word for synchronous operating modes:
• bit 0/1 = 00 → cam shaft 1 active (P-0-0072)
• bit 0/1 = 01 → cam shaft 2 active (P-0-0092)
• bit 0/1 = 10 → cam shaft 3 active (P-0-0780)
• bit 0/1 = 11 → cam shaft 4 active (P-0-0781)
Bit 4 in parameter P-0-0089 indicates the position status of the actual
position value in the actual value cycle (P-0-0753).
P-0-0089, Status word for synchronous operating modes:
• bit 4 = 0 → not homed
• bit 4 = 1 → homed (absolute synchronization can take place)
Bit 5 in parameter P-0-0089 indicates the status of the cam shaft distance
switching.
P-0-0089, Status word for synchronous operating modes:
• bit 5 = 0 → current distance value not active
• bit 5 = 1 → current distance value active
Feedback of Active Cam Shaft
Position Status of Actual
Position Value in Actual Value
Cycle
Status of Cam Shaft Distance
Switching