MPH-02, MPB-02, MPD-02 Drive Control 6-81
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The figures below illustrates the principle of central supply:
module bus module bus module bus
L
+
L
-
+24 V
0 V
DF000122v01_en.fh7
3
mains connection
control voltage
power voltage
(DC bus)
supply
unit
inverter inverter inverter
Fig. 6-54: Mains supply via supply unit
module bus module bus module bus
L
+
L
-
+24 V
0 V
DF000123v01_en.fh7
3
mains connection
control voltage
power voltage
(DC bus)
converter
inverter inverter
converter
Fig. 6-55: Mains supply via converter
Note: The following possibilities and restrictions have to be
observed:
• IndraDrive M inverters can be connected to IndraDrive C
converters! Take DC bus power into account!
• Further HCS02.1 converters that are operated as inverters
may be connected to IndraDrive C devices (converter
HCS02.1).
Exception: There mustn’t be any further HCS03.1 devices
be connected to HCS03.1 devices (inverter operation)!
Central Supply
Kommentare zu diesen Handbüchern