Bosch PIN8 N1 Anleitung zur Fehlerbehebung Seite 307

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 728
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 306
MPH-02, MPB-02, MPD-02 Operating Modes 7-1
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
7 Operating Modes
7.1 Overview of Operating Modes
Supported Operating Modes
The drive firmware MPX-02 supports the following operating modes:
torque/force control
velocity control
position control with cyclic command value input
drive-internal interpolation
drive-controlled positioning
positioning block mode
synchronization modes:
velocity synchronization with real/virtual master axis
phase synchronization with real/virtual master axis
electronic cam shaft with real/virtual master axis
Note: The operating modes supported by the firmware are
depending on the hardware and firmware and are contained in
parameter S-0-0292, List of all operating modes.
Operating Mode Handling
Selecting the Operating Mode
It is possible to configure up to 4 different operating modes (see also
S-0-0292) in the drive. Assignment and configuration are made via the
following parameters:
S-0-0032, Primary mode of operation
S-0-0033, Secondary operation mode 1
S-0-0034, Secondary operation mode 2
S-0-0035, Secondary operation mode 3
Note: If the value "0" was entered in one of these parameters, the
F2007 Switching to non-initialized operating mode error
message is generated when this operating mode is activated.
The operating mode is activated and controlled via bits 8 and 9 in
parameter P-0-0116, Device control: control word:
bit 8/9 = 00: primary mode of operation activated
bit 8/9 = 01: secondary operating mode 1 activated
bit 8/9 = 10: secondary operating mode 2 activated
bit 8/9 = 11: secondary operating mode 3 activated
Activating the Operating Mode
Seitenansicht 306