9-38 Extended Drive Functions MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
800
min
-1
0
min
-1
800
min
-1
0
min
-1
U
out_min
U
out_max
U
out_min
U
out_max
e.g.
speed scaling
=
200min
-1
/V e.g. speed scaling
=
130min
-1
/V
with overflow
e.g. speed scaling
=
130min
-1
/V
without overflow
DK000052v01_en.FH7
800
min
-1
0
min
-1
(display only 650 min
-1
!)
Fig. 9-20: Example of limited or "overflowing" analog output
U
out_min
U
out_max
DK000053v01_en.FH7
e.g.speed scaling
=
200min
-1
/V
with overflow
signal value at 0
V: -
300
min
-1
2000
min
-1
0
min
-1
2000
min
-1
0
min
-1
e.g.
speed scaling =
200min
-1
/V
with overflow
signal value at 0
V: -
700
min
-1
Fig. 9-21: Example of reference-defined analog output
Note: In the case of "overflowing" analog output, the assignment of a
signal value to the output voltage is ambiguous due to the
overflow!
The output of 0 V, for example, can be:
"signal value at 0 V" ± n *output voltage range* "scaling [1/V]"
(n = 1; 2; 3 )